A
. Forward-Stop-Reverse Switch (P/N 9485) – Provides motor reversing and regenerative
braking. Mounts on the enclosure cover and is supplied with a switch seal to maintain
watertight integrity.
B
. Power On/Off Switch (P/N 9486) Disconnects the AC line. Mounts on the enclosure
cover and is supplied with a switch seal to maintain watertight integrity.
C. Signal Isolator SIRC (P/N 8842) Provides isolation between a non-isolated signal volt-
age source and the KBRC-240D. Mounts on the inside of the enclosure cover.
D. Auto/Manual Switch (P/N 9487) When used with the SIRC, it selects either an isolat-
ed signal from the SIRC or from the Main Speed Potentiometer. Mounts on the enclosure
cover and is supplied with a switch seal to maintain watertight integrity.
E. KBRF-200 RFI Filter (P/N 9945) – Provides RFI and EMI suppression. Meets CE direc-
tives.