INTRODUCTION
Thank you for purchasing the KBVF Adjustable Frequency Drive. KB Electronics, Inc. is committed to pro-
viding total customer satisfaction by producing quality products that are easy to install and operate. The
K
BVF is manufactured with surface mount components incorporating advanced circuitry and technology. A
F
inger-Safe Cover is included for added liability protection.
T
he KBVF Adjustable Frequency Drives provide variable speed control for standard 3-phase and Permanent
Split Capacitor (PSC)
1
AC induction motors from 2 thru 5 HP. This manual covers models with single-phase
and 3-phase AC line input. The sine wave coded Pulse Width Modulated (PWM) output operates at a carrier
frequency of 16 kHz, which provides high motor efficiency and low noise. Adjustable linear acceleration and
deceleration are provided, making the drive suitable for soft-start applications.
Due to its user-friendly design, the KBVF AC drive is easy to install and operate. Tailoring to specific applica-
tions is accomplished with selectable jumpers and trimpots, which eliminate the computer-like programming
required on other drives. However, for most applications no adjustments are necessary. For more advanced
programming, PC based Drive-Link™ software is available.
Main features include adjustable RMS Current Limit and I
2
t Motor Overload Protection.
2
In addition,
Adjustable Slip Compensation with Static Auto-Tune and Boost provides high torque and excellent load reg-
ulation over a wide speed range. Power Start™ delivers over 200% motor torque to ensure startup of high
frictional loads. Electronic Inrush Current Limit (EICL™) eliminates harmful AC line inrush current. The drive is
suitable for machine or variable torque (HVAC) applications. With optional Drive-Link™ software, the drive
can be programmed for DC Injection Braking.
For AC line and motor wiring, a barrier terminal block is provided. Other features include: adjustable trimpots
(MIN, MAX, ACC, DEC/B
3
, COMP, CL), customer selectable jumpers (Automatic-Manual Start, Motor
Frequency, Frequency Multiplier, Forward/Reverse). Diagnostic LEDs are provided for power (PWR) and
drive status (ST). A 5 k Main Speed Potentiometer is also included.
A Signal Isolator (built-in on Models KBVF-45,48 and optional on Models KBVF-27, 29) can be used for
unidirectional or bidirectional speed control and accepts voltage and current signal input. Other optional
accessories include: Multi-Speed Board, Programming Kit, and Modbus Communication Module. A connec-
tor is provided for easy installation of accessories.
Notes: 1. Optional software is required for PSC motors contact our Sales Department. 2. UL approved as
an electronic overload protector for motors. 3. In 50 Hz Mode, the DEC/B Trimpot automatically becomes
Adjustable Boost.
3.1 STANDARD FEATURES
Simple to Operate Does not require programming. Uses trimpots and jumpers, which are factory
set for most applications.
Diagnostic LEDs Power on (PWR) and drive status (ST). See Section 12, on page 22 and 23.
Jumper Selection of Drive Output Frequency – Increases the motor speed up to two times the
rated RPM. See Section 6, on page 14 and 15.
Industry Standard Mounting See Section 7, on page 15 and 16.
Finger-Safe Cover Meets IP-20 standard. See Section 5, on page 14.
Models KBVF-29, 48 contain a built-in cooling fan.
Note: GFCI Operation – This drive can operate with GFCIs (optional software required) – contact our
Sales Department.
9
This product complies with all CE directives pertinent at the time of manufacture. Contact our Sales
D
epartment for Declaration of Conformity. Installation of a CE approved RFI filter is required. See RFI
F
ilters & Chokes Selection Guide D-321 (Part No. A42027) for selection of filters to meet the Industrial or
Residential Standard. Additional shielded cable and/or AC line cables may be required along with a signal
isolator (SIVFR (Part No. 9597)).
Vista de página 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 28 29

Comentários a estes Manuais

Sem comentários