9.3 MOTOR CONNECTION – Wire the motor to
T
erminals “U”, “V”, “W”. The terminals are located
on the upper PC board. See Figure 14, on page
17. Motor cable length should not exceed 100 ft
(
30 m) – special reactors may be required – con-
s
ult our Sales Department.
Note: The drive is programmed to operate
3-phase AC induction motors. For PSC motors,
o
ptional software is required – contact our Sales
D
epartment.
9
.4 MAIN SPEED POTENTIOMETER CONNECTION
–
The drive is supplied with a 5 kΩ Main Speed
Potentiometer to control motor speed.
WARNING! Do not earth
ground any Main Speed
Potentiometer terminals.
Note: When mounting the Main
Speed Potentiometer, be sure to
install the insulating disc (supplied)
between the potentiometer and the
panel.
9.4.1 Models KBVF-27, 29 – Wire
the Main Speed
Potentiometer to Terminals
“P1” (low), “P2” (wiper), “P3”
(high). The terminals are locat-
ed on the lower PC board.
See Figure 15.
If installing the SIVFR Signal
Isolator, see Section 9.4.2.
9.4.2 Models KBVF-45, 48 – Wire
the Main Speed
Potentiometer to Terminal
Block TB1 on the SIVFR.
For Unidirectional Speed
Operation: Wire the Main
Speed Potentiometer to
Terminals “+5V” (high), “SIG1”
(wiper), “COM1” (low). Motor
direction is selected with a
Forward-Stop-Reverse Switch wired to Terminals “0V” (common of switch), “FWD”, “REV”. See
Figure 16. If a Forward-Stop-Reverse Switch is not used, a jumper must be installed between
Terminals “0V” and “FWD”, of Terminal Block TB1, in order for the drive to operate.
For Bidirectional Speed Operation
: Wire the Main Speed Potentiometer to Terminals “+5V”
(high), “SIG1” (wiper), “– 5V” (low). Terminals “FWD”, “REV”, “COM1” must be hard wired
together. See Figure 17.
18
Wiper
Low
High
P1
(Supplied) (Front View)
Main Speed Potentiometer
P3P2
FIGURE 15 – MODELS KBVF-27, 29
MAIN SPEED POTENTIOMETER CONNECTION
(
UNIDIRECTIONAL OPERATION)
REV
High
Stop
-5V
TB1
+5V 0V FWD
Forward
Wiper
Potentiometer
Main Speed
(5 k)
Low
Reverse
SIG1 COM1
SIVF
TERMINAL
BLOCK
CUR VOLT
J1
FIGURE 16 – UNIDIRECTIONAL MAIN SPEED POTENTIOMETER &
FORWARD-STOP-REVERSE SWITCH CONNECTIONS
(JUMPER J1 INSTALLED IN “VOLT” POSITION)
REV-5V
TB1
+5V 0V FWD SIG1 COM1
Main Speed
Potentiometer
Wiper
(5 k)
High
Jumper
Low
Jumper
CUR VOLT
J1
SIVF
TERMINAL
BLOCK
FIGURE 17 – BIDIRECTIONAL
MAIN SPEED POTENTIOMETER CONNECTION
(TERMINALS “FWD”, “REV”, “COM1” HARDWIRED)
(JUMPER J1 INSTALLED IN “VOLT” POSITION)